Download
| Product Manual ViroReal® PCV3 |
|
| Material Safety Data Sheet ViroReal® PCV3 |
|
|
|
Background: Porcine circovirus type 3 (PCV3) is a novel circovirus species identified in pigs with porcine dermatitis and nephropathy syndrome (PDNS), reproductive failure, respiratory disease and multi-systemic inflammation. Porcine circovirus is a small, non-enveloped DNA virus that contains a single strand of circular DNA. It belongs to the genus Circovirus in the family Circoviridae.
Description: ViroReal® Kit PCV3 is a real-time PCR for the qualitative detection of the DNA of the capsid gene of porcine circovirus type 3 (PCV3). Our carefully designed primers and probes ensure the highest sensitivity and specificity. The kit consists of an assay mix for the detection of the pathogen as well as a positive control and an internal positive control (IPC) system. To minimize PCR cross-contamination, the included reaction mix contains dUTP and uracil-N glycosylase (UNG).
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| DVEV03613 | 100 | FAM | Cy5 | capsid gene |
| DVEV03653 | 50 | FAM | Cy5 | capsid gene |
Shipping Temperature: -20 °C to +4 °C
- Amplification and detection: DNA of the capsid gene of PCV3
- Real-time PCR with rapid hot-start Taq DNA polymerase
- ROX™ dye as passive reference
- Internal Positive Control System to exclude false-negative results
- Optimized to handle PCR inhibitors
- PCR platforms: runs on all established standard real-time PCR platforms
- Harmonized thermal profiles to run RNA and DNA samples simultaneously
- Available formats: Kit (with reaction mix) or Assay-only
PCR platforms: ViroReal® Kit PCV3 was validated with the ABI® 7500 Fast Real-Time PCR System (fast cycle parameters are not supported, Thermo Fisher Scientific), and was also tested with LightCycler® 480 II (Roche). It is also compatible with other real-time PCR instruments which detect and differentiate fluorescence in the FAM and Cy5 channel (e.g. Mx3005P® (Agilent), qTOWER3G (Analytik Jena), MIC instrument (bio molecular systems) cobas z 480 Analyzer (Roche), and QuantStudio™ 5 / 6 / 7 (Thermo Fisher Scientific)).
Assay: Optional - this product is also available as an assay-only format with primers, probe and a positive control, but without reaction mix.
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| RTGV103 | 100 | FAM | Cy5 | capsid gene |
Shipping Temperature: -20 °C to +4 °C