Download
| Product Manual BactoReal® Kit Riemerella anatipestifer |
|
| Material Safety Data Sheet BactoReal® Kit Riemerella anatipestifer |
|
|
|
Background: Riemerella anatipestifer is a Gram-negative bacterium that causes acute or chronic septicaemia. It primarily affects young ducks and less frequently turkeys and geese throughout the world. There are 21 known serotypes and infection is spread horizontally between birds. Infection may be referred to as Duck Septicaemia, Goose ''flu, Riemerellosis, New Duck Disease and Polyserositis.
Description: BactoReal® Kit Riemerella anatipestifer is a real-time PCR for the qualitative detection of the 16S-23S ribosomal RNA intergenic spacer of Riemerella anatipestifer. Our carefully designed primers and probe ensure highest sensitivity and specificity. The kit consists of an assay mix for the detection of the pathogen as well as a positive control and an internal positive control (IPC) system. To minimize PCR cross-contamination, the included reaction mix contains dUTP and uracil-N glycosylase (UNG).
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| DVEB05913 | 100 | FAM | Cy5 | 16S-23S ribosomal RNA intergenic spacer |
| DVEB05953 | 50 | FAM | Cy5 | 16S-23S ribosomal RNA intergenic spacer |
Shipping Temperature: -20 °C to +4 °C
- Amplification and detection: 16S-23S rRNA spacer of Riemerella anatipestifer
- Real-time PCR with rapid hot-start Taq DNA polymerase
- ROX™ dye as passive reference
- Internal Positive Control System to exclude false-negative results
- Optimized to handle PCR inhibitors
- PCR platforms: runs on all established standard real-time PCR platforms
- Harmonized thermal profiles to run RNA and DNA samples simultaneously
- Available formats: Kit (with reaction mix) or Assay-only
PCR platforms: BactoReal® Kit Riemerella anatipestifer was validated with the ABI® 7500 Fast Real-Time PCR System (fast cycle parameters are not supported, Thermo Fisher Scientific), and was also tested with Mx3005P® (Agilent), qTOWER3G (Analytik Jena), MIC instrument (bio molecular systems), LightCycler® 480 II (Roche) and cobas Z 480 Analyzer (Roche). It is also compatible with other real-time PCR instruments which detect and differentiate fluorescence in the FAM and Cy5 channel (e.g. QuantStudio™ 5 / 6 / 7 (Thermo Fisher Scientific)).
Assay: Optional - this product is also available as an assay-only format with primers, probe and a positive control, but without reaction mix.
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| RTGV232 | 100 | FAM | Cy5 | 16S-23S ribosomal RNA intergenic spacer |
Shipping Temperature: -20 °C to +4 °C