Background:  The porcine circovirus is a non-enveloped virus with single-stranded and circular DNA. It can be classified into two types (PCV1 and PCV2) according to its antigenicity, pathogenicity and genomic difference. PCV1 is considered non-pathogenic while PCV2 infects pigs. PCV2-infection is widespread and essentially all pig herds are infected with PCV2 but relatively few have PCV2-associated disease (PCVAD) including postweaning multisystemic wasting syndrome (PMWS), porcine dermatitis and nephropathy syndrome (PDNS), and porcine proliferative and necrotizing pneumonia (PNP). From piglets, showing PCVAD signs PCV2 can be isolated at high titres.

Description:  ViroReal® Kit PCV2 uses real-time PCR for the detection of the ORF1 of the porcine circovirus type 2 (PCV2) including the three genotypes A, B and C known so far. Our carefully designed primers and probe ensure highest sensitivity and specificity. The assay is designed to detect very small amounts of PCV2 but does not detect PCV1 or PPV. The kit consists of an assay mix for the detection of the pathogen as well as a positive control and an internal positive control (IPC). To minimize PCR cross-contamination,the reaction mix included contains dUTP and uracil-N glycosylase (UNG). The assay allows determination of PCV2 genomic copy numbers in sample material. A Quantitative real-time PCR Standard PCV2 can be ordered separately (order no. PC100).

ViroReal® Kit PCV2
Order Number Reactions Channel Pathogen Channel IPC Target
DVEV00513 100 FAM Cy5 ORF1
DVEV00553 50 FAM Cy5 ORF1
For veterinary use only
Shipping Temperature: -20 °C to +4 °C
Product Features:
  • Amplification and detection: ORF1 gene of PCV2
  • Real-time PCR with rapid hot-start Taq DNA polymerase
  • ROX dye as passive reference
  • Internal Positive Control System to exclude false-negative results
  • Optimized to handle PCR inhibitors
  • PCR platforms: runs on all established standard real-time PCR platforms
  • Harmonized thermal profiles to run RNA and DNA samples simultaneously
  • Available formats: Kit (with reaction mix) or Assay-only

PCR platforms: ViroReal® Kit PCV2 was validated with the ABI® 7500 Fast Real-Time PCR System (fast cycle parameters are not supported, Thermo Fisher Scientific), and was also tested with Mx3005P® (Agilent) and LightCycler® 480 II (Roche). It is also compatible with other real-time PCR instruments which detect and differentiate fluorescence in the FAM and Cy5 channel (e.g. QuantStudio 5 / 6 / 7 (Thermo Fisher Scientific), qTOWER3G (Analytik Jena),MIC instrument (bio molecular systems), cobas Z 480 Analyzer (Roche)).​

Assay: Optional - this product is also available as an assay-only format with primers, probe and a positive control, but without reaction mix.

ViroReal® PCV2
Order Number Reactions Channel Pathogen Channel IPC Target
RTGV100 100 FAM Cy5 ORF1
For veterinary use only
Shipping Temperature: -20 °C to +4 °C
Frequently Asked Questions:

The kit targets the ORF1 gene of PCV2, detected via the FAM fluorescence channel.
PCV2 infection can lead to PCVAD, including postweaning multisystemic wasting syndrome, porcine dermatitis and nephropathy syndrome, and necrotizing pneumonia.
The internal DNA IPC monitors DNA extraction efficiency and PCR inhibition, ensuring accurate and reliable results.
The kit is validated for ABI 7500, LightCycler 480 II, Mx3005P, and others that detect FAM and Cy5 channels.
Primers and probes were designed and validated to detect all PCV2 genotypes (A, B, C) without cross-reactivity with PCV1.
BactoReal® , MycoReal® , ParoReal ® and ViroReal® Kits run with the same thermal cycling conditions.