Download
| Product Manual BactoReal® Kit Bordetella bronchiseptica |
|
| Material Safety Data Sheet BactoReal® Kit Bordetella bronchiseptica |
|
|
|
Background: Bordetella bronchiseptica is a Gram-negative bacterium found as a normal inhabitant of the respiratory tract in a variety of animals such as dogs, pigs, some rodents, as well as humans. In some cases, it causes pneumonia, canine infectious tracheobronchitis (kennel cough), bronchopneumonia in cats, and atrophic rhinitis in pigs. It is widely distributed in the swine population. Here, some strains cause a mild and non-progressive rhinitis that heals spontaneously. However, if toxigenic pasteurella are present in the herd, then a combination of the two organisms can produce severe progressive rhinitis (PAR). Bordetella bronchiseptica can also be a secondary opportunist invader in pneumonia.
Description: BactoReal® Kit Bordetella bronchiseptica is a real-time PCR for the qualitative detection of the bfrA gene of Bordetella bronchiseptica. Our carefully designed primers and probe ensure highest sensitivity and specificity. The kit consists of an assay mix for the detection of the pathogen as well as a positive control and an internal positive control (IPC). To minimize PCR cross-contamination, the reaction mix included contains dUTP and uracil-N glycosylase (UNG).
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| DVEB02413 | 100 | FAM | Cy5 | bfrA gene |
| DVEB02453 | 50 | FAM | Cy5 | bfrA gene |
Shipping Temperature: -20 °C to +4 °C
- Amplification and detection: bfrA gene of Bordetella bronchiseptica
- Real-time PCR with rapid hot-start Taq DNA polymerase
- ROX™ dye as passive reference
- Internal Positive Control System to exclude false-negative results
- Optimized to handle PCR inhibitors
- PCR platforms: runs on all established standard real-time PCR platforms
- Harmonized thermal profiles to run RNA and DNA samples simultaneously
- Available formats: Kit (with reaction mix) or Assay-only
PCR platforms:
BactoReal® Kit Bordetella bronchiseptica was validated with the ABI® 7500 Fast Real-Time PCR System (fast cycle parameters are not supported, Thermo Fisher Scientific), and was also tested with Mx3005P® (Agilent), qTOWER3G (Analytik Jena), MIC instrument (bio molecular systems), LightCycler® 480 II (Roche) and cobas Z 480 Analyzer (Roche). It is also compatible with other real-time PCR instruments which detect and differentiate fluorescence in the FAM and Cy5 channel (e.g. QuantStudio™ 5 / 6 / 7 (Thermo Fisher Scientific)).
Assay: Optional - this product is also available as an assay-only format with primers, probe and a positive control, but without reaction mix.
| Order Number | Reactions | Channel Pathogen | Channel IPC | Target |
|---|---|---|---|---|
| RTGV1250 | 100 | FAM | Cy5 | bfrA gene |
Shipping Temperature: -20 °C to +4 °C